MET08-W Series
Total Manganese Analyzer
The total manganese analyzer delivers excellent accuracy, repeatability, and long-term stability, maintaining reliable measurement performance even under severe water quality fluctuations commonly found in wastewater environments. The system is equipped with high-quality pumps, valves, and critical components, featuring low reagent consumption and minimal waste discharge, which not only meets environmental requirements but also effectively reduces long-term operating and maintenance costs.
Designed with an embedded hardware–software architecture and modular construction, the analyzer ensures stable operation and easy maintenance. Its compact size and flexible installation options make it well suited for long-term continuous monitoring applications. In addition, the manganese ion analyzer supports RS485 digital communication, allowing seamless integration with PLCs, SCADA systems, and cloud-based monitoring platforms to help users establish an intelligent and high-efficiency water quality monitoring and management system.
Designed with an embedded hardware–software architecture and modular construction, the analyzer ensures stable operation and easy maintenance. Its compact size and flexible installation options make it well suited for long-term continuous monitoring applications. In addition, the manganese ion analyzer supports RS485 digital communication, allowing seamless integration with PLCs, SCADA systems, and cloud-based monitoring platforms to help users establish an intelligent and high-efficiency water quality monitoring and management system.
Features
General
Built-in Auto Calibration, Alarm and Log Functions
4~20 mA Analog Output
Auto Measuring After Power Failure Recovery
Low Reagent Alarm
Installation
Flow through
Measurement Method
- Output Signal: RS485 (Modbus RTU protocol), 19,200 bps, 8 data bits, no parity, 1 stop bit; 4~20 mA
- Data Resolution: 16 bits (0.001% FS)
- Surge Protection: 4000 V DC
- Power: 5~12 V DC, 60 mA
- Protection: polarity, overload, short
- Safety: CE, FCC
Built-in Auto Calibration, Alarm and Log Functions
4~20 mA Analog Output
Auto Measuring After Power Failure Recovery
Low Reagent Alarm
Installation
Flow through
Measurement Method
| Model No | Measurement Method | ||||||||
| MET08 Manganese (Mn) |
The sample undergoes a chemical digestion and reaction which manganese compound is converted to colored complex. Incident UV light is absorbed by the sample and measured by the detector. The measurement value depends on the concentation of the sample. | ||||||||
Applications
Drinking water, surface water, groundwater, industry, water treatment, wastewater
Specifications
General
Built-in Auto Calibration, Alarm and Log Functions
4~20 mA Analog Output
Auto Measuring After Power Failure Recovery
Low Reagent Alarm
Installation
Flow through
Measurement Method
- Output Signal: RS485 (Modbus RTU protocol), 19,200 bps, 8 data bits, no parity, 1 stop bit; 4~20 mA
- Data Resolution: 16 bits (0.001% FS)
- Surge Protection: 4000 V DC
- Power: 5~12 V DC, 60 mA
- Protection: polarity, overload, short
- Safety: CE, FCC
Built-in Auto Calibration, Alarm and Log Functions
4~20 mA Analog Output
Auto Measuring After Power Failure Recovery
Low Reagent Alarm
Installation
Flow through
Measurement Method
| Model No | Measurement Method | ||||||||
| MET06-W Chromium (Cr) |
The sample undergoes a chemical digestion and reaction which chromium compound is converted to colored complex. Incident UV light is absorbed by the sample and measured by the detector. The measurement value depends on the concentration of the sample | ||||||||
Models
![]() |