Features
- All-in-One Compact Housing, Built-in Transmitter and Sensors
- Robust IP68 Water Submersible Protection, Directly Installed in the Field, No Cabinet Required
- Plug & Play, On-line Realtime Measurement
- Ultra Low Power Consumption, Ideal for Outdoor Applications
- 1500 N Tensile Strength Kevlar Reinforced Cable
- Surge Protection for Power and RS485 Communication
- RS485 Digital Communication, Minimize Cabling and Engineering Cost
- Standard Modbus RTU Protocol, Direct Connected with PLC, HMI
- Sapphire Glass Windows to Prevent Scratch
- Innovative Nano Coating to Remain Window Clean
- Auto Cleaning Wiper, Less Maintenance
- Dual Beam Light and Temperature Compensation
- Turbidity Measurement and Compensation
- Onboard Memory Allowing Users Easily Calibrate and Configure Sensor at Lab and Distribute to Various
Fields and Sites
- AQCFG Software Tool for Data Monitoring, Calibration, Configuration and Diagnosis
- IECEx/ATEX Ex ia IIB T5 Ga Explosive Proof Certification
Applications
Drinking water, surface water, industry, water treatment, wastewater
Specifications
Measurement Method
The analyzer consists of a light source, a sample cell, and a light detector (photo detector). Incident light is absorbed by the sample, and the light is measured by the detector. The value depends on the amount of absorbance in the sample. The transmitter uses a long life LED and the 180° light method in accordance with International standard to assure accurate measurement values. An automated mechanical wiper is utilized to remain surface clean and remove air bubbles of the optical window in order to maximize the accuracy and minimize the maintenance requirement.
Installation
Submersible, flow through, pipe insertion
SMR47 Color Analyzer
General |
|
Output Signal |
RS485 (Modbus RTU protocol), 19,200 bps, 8 data bits, no parity, 1 stop bit; 4~20 mA (optional) |
Data Resolution |
16 bits (0.001% FS) |
Surge Protection |
4000 VDC |
Power |
5~12 VDC, 45 mA |
Protection |
Polarity, Overload, Short circuit |
Safety |
CE, FCC |
Color |
|
Measurement range |
0~ 100 Hazen (Pt/Co, APHA, PCU)(100 mm)(SMR47-1) ;
0~ 500 Hazen (Pt/Co, APHA, PCU)(20 mm)(SMR47-2) ;
0~ 2,000 Hazen (Pt/Co, APHA, PCU)(5 mm)(SMR47-3) |
Accuracy |
±5%±1 Hazen in standard solution |
Resolution |
0.01 Hazen (Pt/Co) |
Repeatability |
±3% Hazen in standard solution |
Light source |
LED 390 nm |
Beam Angle |
180 ° |
Light Path Length |
5, 20, 100 mm |
Process Flow Rate |
Max. 3m/sec |
Operation pressure |
Max. 10 Kgf/cm² |
Operating temperature |
0~60 °C |
Response time |
1 sec |
Protection |
IP68 |
Connection |
1”-11 PT; 5-pin M16 plug |
Housing |
SS316L; Titanium |
Dimension |
Φ 50 X 305 mm |
Weight |
analyzer: approx. 1 Kg (SS316L); approx. 0.8 Kg (Titanium) ; Cable: 80 g/m |
Turbidity |
|
Light source |
LED 880 nm |
Measurement range |
0~1,000 NTU |
Accuracy |
±3% measured value |
Resolution |
0.001 NTU |
Repeatability |
±1% measured value |