Products

Algae Analyzer
Blue Green Algae Analyzer

SMR36 Series

Blue Green Algae Analyzer

Description
The Blue Green Algae Analyzer is connected directly via RS485 communication interface, providing simple, reliable, cost-saving process data with remote monitoring,calibration, configuration and diagnostics capabilities.Housing in a robust IP68 proof enclosure, 1500 N tensile strength Kevlar reinforced cable, up to 1.2 km digital data transmission, the transmitter is ideally used in water/wastewater industry.
Features
<
  • Robust IP68 Water Submersible Enclosure, Solution Without Cabinet
  • On-line Realtime Measurement
  • Ultra Low Power Consumption, Ideal for Outdoor Applications
  • High Reliability, Drift Free
  • Surge Protection for Power and RS485 Communication
  • Software Configuration Calibration and Data Monitoring
  • Standard Modbus RTU Protocol, Direct Connected with PLC, HMI, Eliminate I/O Module Cost
  • 1.2 Km RS485 Digital Communication, Minimize Cabling and Engineering Cost
  • Innovative Nano Coating to Remain Window Clean
  • Optional Auto Cleaning Wiper, Almost No Maintenance
  • Onboard memory allowing users to easily calibrate and configure sensor at lab and distribute to various fields sites
Specification
SMR36 Blue Green Algae Analyzer  
Parameter SMR36-1: Phycocyanin (PC)
SMR36-2: Phycoerythrin (PE)
Measurement range SMR36-1: 0~500 μg/L; 0~200,000 cells/ml
SMR36-2: 0~300 μg/L; 0~600,000 cells/ml
Accuracy Linearity R2 > 0.999 for serial dilution of Rhodamine WT solution equivalents
Resolution 0.01 μg/L; 1 cells/ml
Repeatability ±1% FS
Light source SMR36-1: LED 530 nm 
SMR36-2: LED 610 nm
Operation pressure Max.5 Kgf/cm2
Operating Temperature 0~85 °C
Process flow rate 0.1~10 m/s
Response time 1 secs
Protection IP68
Housing SS316L; Titanium
Dimension Φ 34 Χ 226 mm
Weight analyzer: approx.500 g; cable: 80 g/m
Typical Application
Surface water
General
  • Output Signal: RS485 (Modbus RTU protocol), 19,200 bps, 8 data bits, no parity, 1 stop bit; 4~20 mA (optional)
  • Data Resolution: 16 bits (0.001% FS)
  • Surge Protection: 4000 V DC
  • Power: 3.6~12 V DC ±10%, 5 mA
  • Protection: polarity, overload, short circuit
  • Safety: CE, FCC
Typical Applications
  • Surface water
Measurement Method
  • It is based on fluorescent optical lechnology. A fluorometer generates the wavelength of light required to excite the analyte of interest, it selectively transmits the wavelength of light emitted, then it measures the intensity of the emitted light. The emitted light is proportional to the concentration of the analyte being measured.
Ordering 
Note
Standard cable length is 3 m, customized length is available upon request
History
    3Inquiry