ROD Flooding Level Logger
Frequently Asked Questions
-
Q1
Product Basics
A- Product Basics
Q1: About ROD?
ROD is AQUAS’ compact and cost-effective flood water-level data logger, designed primarily for flood, water-level, storm rainfall, and ponding monitoring.
Q2: Where is ROD suitable for installation?
ROD is suitable for flood-prone locations, streets, underpasses, tunnels, outdoor flood monitoring points, and stormwater monitoring sites.
Q3: What does ROD mainly monitor?
ROD mainly monitors flood water level. It can also be used with level sensors, SMR sensors, and I/O signals for flood early warning, data logging, and data upload.
Q4: Does ROD require an external power supply?
Not necessarily. ROD uses an ultra-low-power design and can operate continuously on battery power without an external power source. Depending on the model, it can also use external power, solar panels, or external batteries.
Q5: Is ROD suitable for long-term outdoor use?
Yes. ROD uses an integrated fully sealed IP68 rugged waterproof enclosure and can be installed directly in rainy, flooded, or humid outdoor environments.
Q6: Does ROD require an electrical control cabinet?
In general, no. ROD has an IP68 waterproof enclosure and can be installed directly outdoors or in flood-prone sites, reducing the need for control cabinets and installation costs.
Q7: How many SMR sensors can ROD connect to?
ROD can connect up to four SMR digital sensors or MAX multiparameter analyzers through the RS485 sensor port.
Q8: Can ROD upload data in real time?
Yes. ROD can transmit real-time values, alarms, and logged data to a server via 4G, GPRS, NB-IoT, WiFi, LoRa, satellite communication, and other communication options.
Q9: Does ROD support AQWEB?
Yes. ROD can work with the AQWEB cloud management platform for remote monitoring, alarm overview, trend charts, data analysis, and report queries.
Q10: Does ROD have a warning light?
Yes. The manual shows that ROD can be used with a warning light, which is triggered when an alarm occurs.
Q11: Does ROD support GPS?
GPS is optional. If a GPS module is installed, ROD can search coordinates and store location records. If GPS is not installed, coordinates can also be entered manually.
Q12: Does ROD support SMS alarms?
Yes. ROD can be configured with up to 10 mobile phone numbers and can send SMS notifications when an alarm starts or ends.
- Product Basics
-
Q2
Product Features and Applications
A- Product Features and Applications
Q1: What are the main advantages of ROD?
ROD features a 2-inch-diameter design suitable for ground installation, ultra-low power consumption, solar panel and lithium battery power options, an IP68 rugged waterproof enclosure, real-time water-level detection, automatic flood alarm notification, data logging, and data upload.
Q2: Why is ROD suitable for flood monitoring?
ROD can be installed directly in flood-prone areas and provides a waterproof enclosure, low-power operation, real-time water-level detection, and alarm upload functions, making it suitable for storm and flood early-warning applications.
Q3: Is ROD suitable for underpass monitoring?
Yes. The manual lists underpasses and tunnels as application sites, which are suitable for areas where water levels change quickly and immediate alarms are required.
Q4: Is ROD suitable for street flooding monitoring?
Yes. ROD can be installed on flood-prone streets or low-lying locations and can be used with a warning light and remote alarms to improve on-site warning capability.
Q5: Can ROD be used with rainfall or meteorological sensors?
Yes. The product features state that the sensor port can connect to water-level, rainfall, flow velocity, flow direction, temperature and humidity, wind direction, wind speed, sunlight, barometric pressure, PM2.5, and other sensors.
Q6: Does ROD support data backfilling?
Yes. When communication is unavailable, ROD can store data locally and automatically backfill the data after communication is restored.
Q7: Can ROD upload data to two servers at the same time?
Yes. The manual states that log and alarm data can be uploaded simultaneously to two data servers for dual redundancy.
Q8: Can ROD integrate with databases or monitoring systems?
Yes. ROD can integrate with platforms or monitoring systems through FTP, MQTT, RESTful, Modbus TCP, OPC Server, SQL / MySQL, and related methods.
- Product Features and Applications
-
Q3
Hardware, Dimensions, and Installation
A- Hardware, Dimensions, and Installation
Q1: What are the main hardware components of ROD?
ROD mainly includes the host unit, water-level staff gauge, warning light, water-level sensor, I/O port, RS485 sensor port, solar panel, and communication module.
Q2: What are the main ports on ROD?
ROD mainly includes Port 0 for system control, Port 1 for RS485 sensors, Port 2 for I/O, and connection points for the solar panel, warning light, water-level sensor, and related components.
Q3: What is Port 0 used for?
Port 0 is the system control port. It can be connected to a PC via CAB06 for AQCFG configuration, alarm settings, control parameters, and data upload/download.
Q4: What is Port 1 used for?
Port 1 is the RS485 sensor port. It can connect to a water-level sensor, SMR sensor, or MAX multiparameter analyzer.
Q5: What is Port 2 used for?
Port 2 is the I/O port. It supports two DI channels for status input or pulse/counting mode.
Q6: What is the purpose of the ROD staff gauge?
The ROD staff gauge provides a visual reference for on-site water-level height, allowing personnel to read flood depth directly at the site.
Q7: What is the water-level measurement range of ROD?
The manual specifications list the water-level module measurement range as 0–3 m.
Q8: What is the water-level measurement accuracy of ROD?
The manual specifications list the water-level module accuracy as 0.3 cm, with a 0.1 cm optional version available.
Q9: What are the dimensions of the ROD host unit?
The dimension drawing in the manual shows the host unit is approximately 85 mm × 171 mm × 52 mm.
Q10: What staff gauge lengths are available for ROD?
The ordering information lists cable length / staff gauge length options as none, 100 cm, 200 cm, or custom lengths from 010 to 999 cm.
Q11: How can ROD be installed?
ROD can be fixed directly to the ground. The installation diagram shows the host, staff gauge, and bolts used for mounting.
Q12: What should be noted during ROD installation?
Ensure that the host unit, staff gauge, water-level sensor, and warning light are firmly fixed, and avoid pulling, compressing, or damaging the water-level sensor or cables.
- Hardware, Dimensions, and Installation
-
Q4
Power Supply and Battery
A- Power Supply and Battery
Q1: What power supply options does ROD support?
ROD supports external power, internal primary battery, internal rechargeable battery, solar panel, and external battery power options.
Q2: What is the input voltage of ROD?
The manual specifications list the input voltage as 5 VDC ±10%, 1A.
Q3: What internal battery options are available for ROD?
The manual lists BAT10 as a 3.6 VDC 13Ah primary lithium battery and BAT05-1 as a 3.6 VDC 13Ah rechargeable lithium battery.
Q4: Can ROD be used with a solar panel?
Yes. ROD can be used with a solar panel. The device connection diagram lists the solar panel specification as 4.5 W, 6.6 VDC, 500 mA.
Q5: How long can ROD operate on battery power?
The manual states that ROD can operate long term using battery or solar power. Battery life in the specifications varies depending on logging frequency, upload frequency, alarm frequency, number of sensors, and site conditions.
Q6: What should be done after replacing a primary battery?
After replacing a primary battery, press “Reset” on the AQCFG system page so the system can correctly recalculate battery capacity.
Q7: Why is it important to select the correct power mode?
The power mode affects battery voltage, capacity, and remaining runtime estimation. Incorrect settings may cause inaccurate battery display or maintenance judgment.
Q8: Does ROD have a low-voltage alarm?
Yes. ROD can be configured with a low-voltage alarm on the alarm page to issue an alarm or notification when battery voltage is too low.
Q9: What are the risks of using an incorrect battery?
The manual warns that replacing the battery with an incorrect type or using a non-original charger may create an explosion risk. Used batteries must be handled according to the manufacturer’s instructions.
- Power Supply and Battery
-
Q5
AQCFG Software Installation and Connection
A- AQCFG Software Installation and Connection
Q1: Which software is used to configure ROD?
ROD uses AQUAS AQCFG software for device search, connection, system configuration, communication settings, sensor settings, alarm settings, data export, and firmware updates.
Q2: How is AQCFG installed?
Insert the CD or USB drive, select the AQCFG folder, click the Setup icon to start installation, follow the Next steps, and finally click Install to complete the installation.
Q3: How does ROD connect to a computer?
Use the CAB06 communication cable to connect ROD to the PC, then open AQCFG software for device search and configuration.
Q4: What must be installed before using CAB06?
Install the USB Driver first. Open the USB Driver folder and run CDM20824_Setup. After installation, a Serial COM Port will appear in Device Manager.
Q5: What should be set before searching for ROD in AQCFG?
Click “Setup” and select the COM Port, baud rate, and ID range to be scanned, then close the setup page.
Q6: What is the default AQCFG baud rate for ROD?
The manual’s quick operation and connection instructions indicate a default baud rate of 115200 bps.
Q7: How do you enter the system after ROD is found?
Click “Link” or double-click the detected ROD device to enter the system settings page.
Q8: Does AQCFG automatically display the USB COM Port?
Yes. The manual screen indicates that the USB COM Port is automatically displayed after the USB connection is made.
Q9: What should be checked if AQCFG cannot scan ROD?
Check whether CAB06 is correctly connected, the USB Driver is installed, the correct COM Port is selected, the baud rate is 115200, the ID range includes the device ID, and ROD is powered on.
Q10: What should be done first after entering the ROD settings page?
Click the System ON button first. The system must be powered on before configuration and data logging can be performed.
- AQCFG Software Installation and Connection
-
Q6
Host System Settings
A- Host System Settings
Q1: What can be configured on the ROD system page?
The system page allows viewing and configuration of model, serial number, location, area, sub-area, system time, battery mode, battery voltage, battery capacity, communication rate, and Modbus ID.
Q2: Can the model field be modified?
No. The model is created during production and is used to verify the hardware configuration. It cannot be modified by the user.
Q3: What is the serial number?
The serial number is the unique device ID for each ROD unit and is used for device identification, management, and platform mapping.
Q4: What can be entered in the location field?
The location field can be customized by the user and can contain up to 20 letters, making it easier for AQWEB to manage and identify the device location.
Q5: What are the area and sub-area fields used for?
Area and sub-area can be used for platform classification, such as distinguishing administrative districts, watersheds, sites, or monitoring zones.
Q6: How is the ROD system time synchronized?
PC / Server synchronization can be selected. After pressing Confirm, the system time synchronizes with the server. If a GPS module is installed, GPS-related synchronization functions may also be used.
Q7: Why is correct system time important?
System time affects data logs, alarm events, trend charts, and uploaded data timestamps. Incorrect time can make data interpretation difficult.
Q8: How are system settings saved?
After completing each field setting, press “Confirm” again to save the data.
Q9: Can the ROD Modbus ID be configured?
Yes. The system page can configure the ID. The range depends on the software screen and device settings.
- Host System Settings
-
Q7
4G / GPRS / FTP Communication
A- 4G / GPRS / FTP Communication
Q1: Which communication methods does ROD support?
Depending on the model, ROD can support GPRS, 4G, NB-IoT, WiFi, LoRa, satellite communication, Ethernet, Bluetooth, and RS485.
Q2: What data can ROD upload?
ROD can upload initial configuration parameters, real-time values, alarm data, log data, and water-level monitoring data.
Q3: What should be done before configuring 4G or GPRS?
Enable the module first by checking “Enable” and pressing Confirm. After completing the settings, press Confirm again to save the data.
Q4: What does the 4G status Standby mean?
Standby means the communication module is off or in standby mode.
Q5: What does Try Connecting mean?
Standby → Try Connecting means the communication module is establishing a connection.
Q6: What does Connected → Data Communication mean?
It means the connection is successful and data is being transmitted.
Q7: How is communication signal strength evaluated?
AQCFG displays signal strength from 0% to 100% and the dBm value. The manual states that if the dBm value is greater than -93 dBm, the signal is too weak and may not connect to the server.
Q8: How should APN be configured?
APN, username, and password should be configured according to the telecom provider’s network information. They can also be obtained by selecting the country and carrier from the network provider list on the right side, or by asking the carrier.
Q9: What needs to be configured in CCS mode?
CCS mode requires the server IP and server port. The manual lists the default server port as 502.
Q10: What is the default AQUAS cloud server setting?
The quick setup screen in the manual lists the default AQUAS cloud server as 118.163.120.143:502. For actual projects, use the shipment settings or platform information.
Q11: Can ROD be configured with a backup server?
Yes. If ROD data needs to be sent to a second server at the same time, enable the backup server and enter the second server IP and Port.
Q12: What information is required for FTP mode?
FTP mode requires the FTP server IP, FTP Port, username, and password. The default FTP Port is 21.
Q13: What is CCS / FTP mode?
If both the CCS and FTP servers need to receive uploaded ROD data, select CCS / FTP mode.
Q14: How is communication confirmed after setup?
Click “Connection Test” to confirm whether data can be successfully uploaded to the server.
- 4G / GPRS / FTP Communication
-
Q8
GPS and SMS
A- GPS and SMS
Q1: Is GPS a standard feature of ROD?
GPS is optional. If the GPS module is not installed, coordinates can be entered manually.
Q2: What can ROD GPS do?
GPS can search coordinates, record location, synchronize data, and help AQWEB display the monitoring station location.
Q3: What does GPS status off mean?
off means the GPS module is turned off.
Q4: What does GPS status Searching mean?
Searching means the GPS module is enabled and is searching for satellite positioning.
Q5: What does GPS status Position mean?
Position means positioning is complete.
Q6: How is the GPS signal displayed?
AQCFG displays GPS module signal strength from 0% to 100%.
Q7: Can GPS coordinates be recorded periodically?
Yes. After “Periodic” is selected, ROD records GPS coordinate values together with other data.
Q8: When is GPS continuous mode suitable?
Continuous mode keeps the GPS module on. The manual recommends using this mode when external power is available.
Q9: What is GPS search mode?
Search mode manually turns on the GPS function. After one search is completed, the GPS function automatically turns off whether positioning succeeds or fails.
Q10: What is the shortest interval for GPS periodic mode?
The manual states that the shortest interval for GPS periodic mode is 5 minutes.
Q11: How many SMS numbers can ROD configure?
Up to 10 mobile phone numbers can be configured.
Q12: When can SMS notifications be sent?
Each mobile number can be configured to receive SMS notifications when an alarm starts and when an alarm ends.
Q13: Why can the alarm-end SMS not be selected directly?
The manual notes that “Alarm Start” must be selected before “Alarm End” can be selected.
Q14: How is the SMS function tested?
Press “SMS Test”; the host will send a test SMS to the first mobile phone number.
- GPS and SMS
-
Q9
Water-Level Sensor, Barometric Compensation, and Sensors
A- Water-Level Sensor, Barometric Compensation, and Sensors
Q1: How does ROD connect to a water-level sensor?
Connect the SMR02 water-level sensor to Port 1 of the ROD host, then configure and scan it on the AQCFG sensor port page.
Q2: What is the default communication setting for ROD Port 1?
The manual’s water-level sensor setup instructions list the Port 1 default as 19200.N81. Actual settings should be adjusted according to the SMR02 water-level sensor configuration.
Q3: What are the station ID restrictions for SMR sensors?
The manual states that sensor station IDs must be set from 1 to 8. Sensors outside this range will not be read.
Q4: How do you enter settings after SMR02 is scanned?
Click Device01-SMR02 in the AQCFG tree, or quickly double-click the SMR sensor in the list to open the water-level sensor settings page.
Q5: What can be configured on the SMR02 settings page?
Liquid density, water-level unit, logging method, and water-level sensor elevation can be configured.
Q6: What readings does SMR02 display?
SMR02 can display water-level height and temperature values.
Q7: What is water-level sensor elevation?
Water-level sensor elevation is the reference setting used to calculate on-site water-level height and can be set according to the site staff gauge or installation reference.
Q8: Why does ROD require barometric compensation?
The manual states that SMR02 is a water-level sensor without vent-tube compensation, so a barometric module is required for measurement compensation.
Q9: How is barometric compensation configured?
In the AQCFG tree, click “Barometric Compensation,” enable it, select the logging method and barometric pressure display unit, and press Confirm to display the current barometric pressure value.
Q10: How is barometric compensation calibrated?
After ROD is connected to SMR02 and communication is successful, remove the SMR02 water-level sensor from the measurement tank and place it in air. Enable water-level compensation, select On Board as the compensation method, and click zero calibration. When the status shows OK, calibration is complete.
Q11: Can ROD connect to other SMR sensors?
Yes. The manual screens show examples of SMR04 pH, SMR05 ORP, SMR07 conductivity, SMR09 dissolved oxygen, and other sensors. Actual configuration should follow the product configuration and project requirements.
Q12: Can sensors be configured for periodic or alarm logging?
Yes. The sensor settings page allows periodic logging or alarm logging to be selected so that the system stores data according to the configured conditions.
- Water-Level Sensor, Barometric Compensation, and Sensors
-
Q10
I/O, Alarms, and Data Logging
A- I/O, Alarms, and Data Logging
Q1: What can the ROD I/O module do?
The ROD I/O module is used for digital input and supports status mode and counting / rainfall mode.
Q2: What is status mode?
Status mode is used to record DI status, such as switch, contact, or equipment status.
Q3: What is counting / rainfall mode?
Counting / rainfall mode converts each pulse into a specified value and unit, such as rainfall, flow, or accumulated quantity.
Q4: What needs to be configured in counting mode?
Configure the value and unit represented by each pulse, the real-time display unit, instantaneous value averaging time, logging method, and initial accumulated value.
Q5: Can the accumulated value be cleared?
Yes. Click Clear to reset the accumulated value to zero.
Q6: Does ROD support automatic reset?
Yes. The manual states that the accumulated value can be reset automatically at selected times such as 00:00, 08:00, 12:00, or 18:00 every day.
Q7: What alarms can ROD configure?
ROD can configure system alarms, sensor alarms, and I/O module alarms, such as low voltage, communication failure, high/low water-level alarms, and DI status alarms.
Q8: What alarm levels can be configured?
Alarm levels such as HH, H, L, and LL can be configured, along with corresponding thresholds and enable conditions.
Q9: What happens when an alarm occurs?
When an alarm occurs, ROD can record the alarm event, upload data, send SMS notifications, and trigger the ROD warning light.
Q10: Can ROD export data?
Yes. Log and alarm data can be searched and exported from the AQCFG Import / Export page.
Q11: What is the data logging capacity of ROD?
The manual specifications list an approximate capacity of 2,000,000 data records, with support for periodic logging and alarm logging.
- I/O, Alarms, and Data Logging
-
Q11
Operation Settings and Data Upload
A- Operation Settings and Data Upload
Q1: What can be configured in operation settings?
Operation settings include system operation, alarm sampling cycle, logging cycle, data upload mode, communication schedule, and retry count.
Q2: Does ROD support continuous operation?
Yes. After “Continuous” is selected, the system can operate continuously for 24 hours or continuously according to the configured time.
Q3: Does ROD support scheduled operation?
Yes. After “Schedule” is selected, start and end dates/times can be configured, and the system operates during selected time periods.
Q4: What is the alarm sampling cycle?
The alarm sampling cycle is the interval at which the system scans sensor or I/O values and determines whether an alarm has occurred.
Q5: What is the logging cycle?
The logging cycle is the interval at which the system writes water-level, sensor, or I/O data into the log records.
Q6: Can logging be accelerated during an alarm?
Yes. Operation settings can define the event logging interval during an alarm period.
Q7: Can data upload be scheduled at fixed intervals?
Yes. ROD can be configured for timed upload to send data back to the server according to the configured time.
Q8: Can data upload follow a schedule?
Yes. If Schedule is selected, the system uploads data only during the selected time periods.
Q9: Can data be uploaded immediately when an alarm occurs?
Yes. ROD can upload data immediately when an alarm occurs, improving the timeliness of flood early warning.
Q10: What happens if data upload fails?
ROD can be configured with a retry count. If upload fails, it will retry according to the settings and can backfill data after communication is restored.
- Operation Settings and Data Upload
-
Q12
Firmware Update and Maintenance
A- Firmware Update and Maintenance
Q1: Can ROD firmware be updated?
Yes. The AQCFG system firmware page can load the correct .aqs firmware file and perform the update.
Q2: What should be noted before firmware update?
Before updating, ensure that only one device is connected to avoid upload failure or an unrecoverable device condition.
Q3: Can the firmware update process be interrupted?
No. After the update starts, it must not be interrupted. Wait until the update is complete.
Q4: What should be done after firmware update is complete?
The manual states that after the update is complete, go to the settings page under Import / Export and click “Restore” to restore ROD to factory settings. After reconnecting and powering on, delete data on the log page to ensure normal host operation.
Q5: Does ROD require regular maintenance?
Yes. Regularly inspect the enclosure, waterproof connectors, fixing bolts, water-level sensor, staff gauge, warning light, battery, solar panel, communication signal, and data upload status.
Q6: What should be done if a ROD cable is damaged?
If a sensor or device cable is damaged, contact AQUAS Customer Service. Do not cut, fold, damage, or replace the power cable by yourself.
Q7: Can ROD be modified by the user?
It is not recommended. Do not disassemble or modify the product or components unless explicitly described in the manual.
Q8: What should be noted when using ROD outdoors?
Confirm that the host seal is intact, screws are tightened, cables are secured, the solar panel is not shaded, the warning light can be triggered normally, and communication signal and battery status are normal.
Q9: What should be checked after ROD is flooded?
Check whether the host, staff gauge, water-level sensor, connectors, and cables are loose or damaged, and confirm whether data is recorded and uploaded normally.
- Firmware Update and Maintenance
-
Q13
Troubleshooting
A- Troubleshooting
Q1: What should I do if ROD cannot connect to the computer?
Check whether CAB06 is correctly connected, the USB Driver is installed, Device Manager shows a Serial COM Port, the correct COM Port is selected, and the baud rate is 115200.
Q2: What should I do if AQCFG cannot scan ROD?
Check whether ROD is powered on, the ID range includes the device ID, the COM Port is correct, and the communication cable is working, then scan again.
Q3: What should I do if ROD cannot upload data?
Check whether the communication module is enabled, the SIM card is normal, the APN is correct, the server IP and Port are correct, and then perform a connection test.
Q4: What should I do if the 4G signal is too weak?
If the dBm value is greater than -93 dBm, the signal is too weak. Adjust the antenna location, installation position, or confirm telecom signal coverage.
Q5: What should I do if FTP upload fails?
Check whether the FTP server IP, Port 21, username, and password are correct, and click Connection Test.
Q6: What should I do if SMS messages are not received?
Check whether SMS is enabled, the mobile number is correct, the SIM card supports SMS, alarm conditions are configured, and test the function using SMS Test first.
Q7: What should I do if GPS cannot obtain a position?
Check whether a GPS module is installed, GPS is enabled, the site is not blocked, and signal strength is sufficient. If GPS is not installed, use manual coordinate entry.
Q8: What should I do if the water-level sensor cannot be scanned?
Check whether SMR02 is connected to Port 1, Port 1 communication settings match 19200.N81 or the sensor settings, and the sensor ID is within the range of 1 to 8.
Q9: What should I do if the water-level reading is inaccurate?
Check whether the water-level sensor installation position, liquid density, water-level unit, sensor elevation, and barometric compensation settings are correct. Re-run barometric compensation zero calibration if necessary.
Q10: What should I do if barometric compensation fails?
Confirm that SMR02 is successfully connected, remove the water-level sensor and place it in air, then select the On Board compensation method and perform zero calibration again.
Q11: What should I do if the warning light does not turn on?
Check whether alarm conditions are enabled, an alarm has actually occurred, warning light wiring is normal, and alarm output settings are correct.
Q12: What should I do if data is not being recorded?
Check whether System ON is active, the logging cycle is configured, sensor or I/O logging mode is selected, and the data storage and Import / Export page are functioning normally.
Q13: What should I do if the battery capacity display is inaccurate?
Check whether the power mode and battery type are correct. If a primary battery was replaced, press “Reset” to recalculate battery capacity.
Q14: What should I do if firmware update fails?
Confirm that only one device is connected, the firmware file version is correct, and power and communication remain stable during the update. If it still fails, contact AQUAS technical support.
- Troubleshooting